Ingersoll Rand 49164395 Air Filter Element | Donaldson FPG10 RadialSeal

Ingersoll Rand 49164395 air filter element built to Donaldson FPG10 two-stage RadialSeal specification. 99.9% filtration efficiency (ISO 5011), 208 mm OD x 106 mm ID x 409 mm length, tool-free fitment. Export-ready for compressor distributors and OEM procurement.

Contact Sales WhatsApp
  • Export packaging & documentation support
  • OEM / ODM customization available
  • Sample and bulk order workflow

Product Overview

49164395 is the intake air filter element for Ingersoll Rand screw air compressors, manufactured to the Donaldson FPG10 specification.

FPG10 is a two-stage intake filtration system. Air first passes through an integrated tangential pre-cleaner: the tangential inlet spins the airflow at high speed, and centrifugal force drives coarse particles to the housing wall. Roughly 85% of coarse dust is separated before it reaches the primary element and is discharged automatically through the Vacuator dust valve at the base of the housing. Pre-cleaned air then enters the primary element, where cellulose filter media performs fine filtration. The benefit is clearest in dusty environments: the primary element carries only the fine-particle load, so service life stays long even under heavy dust exposure.

Sealing also differs from conventional air filters. FPG uses Donaldson's RadialSeal technology: a one-piece molded polyurethane end cap forms a radial seal directly against the housing outlet tube, eliminating the glued gasket used on older axial elements. Fewer parts mean fewer failure points — gasket aging, detachment, and misalignment are no longer possible with the FPG design, and no tools are required for installation or removal.

Key Specifications

ItemValue
Part Number49164395
Product NameAir Filter Element
BrandIngersoll Rand
Specification SourceDonaldson FPG10 (two-stage RadialSeal)
Role in AssemblyPrimary Element
Dimensions208 mm OD x 106 mm ID x 409 mm length
SealingRadialSeal (molded polyurethane radial seal, no gasket)
Net WeightApprox. 1.88 kg
Filtration Efficiency99.9% (ISO 5011)
Pre-Cleaner EfficiencyUp to 85% coarse dust removal
Rated AirflowUp to 346 cfm / 9.8 m3/min
Recommended Replacement2,000 hours or 3 months

Technical Parameters

Filtration Performance

ParameterValue / Note
Filtration Rating5 micron class (primary element)
Filtration Efficiency99.9% (tested to ISO 5011)
Pre-Cleaner EfficiencyUp to 85% coarse dust removal (tangential pre-cleaner stage)
Filter ClassTwo-stage design: centrifugal pre-cleaning plus cellulose primary element; HVAC classification (EN 779) does not apply
Dust Holding CapacityApprox. 1,200 g

Why the two-stage design matters: on a single-stage filter, the media must handle both coarse and fine particles, so coarse dust builds up on the surface quickly and restriction rises fast. By shifting the coarse load to the centrifugal pre-cleaner, FPG10 markedly improves the primary element's loading profile — a key reason the design is widely used on construction machinery and generator sets operating in dusty conditions.

Flow and Restriction

ParameterValue / Note
Rated AirflowUp to 346 cfm / 9.8 m3/min (air cleaner assembly rating)
Face VelocityApprox. 0.038 m/s
Initial Pressure DropApprox. 0.5-1.0 kPa (approx. 50-100 mmH2O)
Operating DifferentialFrom new-element initial restriction up to the clogging alarm value
Alarm / Final RestrictionPer the unit's intake restriction indicator (yellow / red zone)
Restriction vs. EnergyEach 1 kPa rise in intake restriction increases unit energy consumption by roughly 1%

Restriction and energy consumption

Rising intake restriction lowers intake pressure and density, so the unit must work harder to hold its discharge pressure and flow, and specific power rises. Calculated on compression ratio theory at 0.7 MPa discharge and 101.3 kPa atmospheric:

Intake RestrictionCompression RatioRelative Energy Increase
0 kPa (new element)7.91Baseline
2 kPa8.07+2.0%
4 kPa8.24+4.1%
6 kPa8.41+6.3%

Practical implication: as an element moves from new to heavily clogged (0 to 6 kPa), unit energy consumption climbs by roughly 6%. That ongoing electricity cost normally far exceeds the price of one filter element — which is why the FPG10 housing provides a restriction indicator port, so replacement timing is set by actual restriction rather than calendar estimates.

Dimensions and Installation

ParameterValue / Note
Dimensions208 mm OD x 106 mm ID x 409 mm length
ConstructionPleated cylindrical element, two-stage RadialSeal primary element
Effective Filter AreaApprox. 4.3 m2
Pleat CountApprox. 103 pleats
Pleat SpacingApprox. 4.8 mm
Mounting InterfaceRadial push-in; end cap seals against housing outlet tube
SealingRadialSeal — one-piece molded polyurethane end cap forms the radial seal, no separate gasket
Companion ElementSafety element mounted inside the primary element as backup protection

Procurement note: when cross-checking replacements, verify all three dimensions — 208 mm OD, 106 mm ID, 409 mm length. The FPG design seals radially; push the element in until the end cap contacts the outlet tube, with no additional gasket. Do not add a gasket — it will break the radial seal fit.

Materials

ParameterValue / Note
Filter MediaCellulose paper to FPG10 specification
Media WeightApprox. 130 g/m2
Inner / Outer SupportGalvanized steel perforated support (inner cage and outer screen)
End CapOne-piece molded polyurethane (PU) end cap, encapsulating both media ends and the sealing surface
SealRadialSeal formed by the polyurethane end cap itself; no separate O-ring or gasket
BondingMolded integrally with the end cap; no separate adhesive layer

Design note: a conventional axial element uses a metal end cap, glued gasket, and separate seal ring — three parts, any of which can age and cause bypass. FPG encapsulates the end cap, sealing surface, and media ends in a single polyurethane body, reducing part count and improving seal reliability. This is also what enables tool-free servicing.

Operating Tolerance

ParameterValue / Note
Operating TemperatureContinuous 83 deg C
Relative HumidityUp to 80% RH, non-condensing
Burst StrengthMedia burst strength approx. 200-400 kPa (per ISO 2758 paper burst test)
Collapse ResistanceElement withstands intake alarm differential without collapse (layer-by-layer support in RadialSeal construction)
Special FunctionTwo-stage filtration (integrated tangential pre-cleaner) plus Vacuator automatic dust valve
HousingFPG housing is molded plastic — corrosion-resistant and vibration-tolerant

Service Life and Maintenance

ParameterValue / Note
Service Life2,000 hours or 3 months, whichever comes first
High-Dust EnvironmentsFollow restriction indicator readings; schedule replacement once restriction enters the yellow zone
Storage Shelf LifeApprox. 2-3 years (unopened, dry, ventilated conditions)

Applicable Standards

ItemContent
Product StandardISO 5011 (intake air filters for internal combustion engines and compressors — performance testing); efficiency figures are measured to this standard
Construction StandardDonaldson FPG / FRG series air cleaner specification (RadialSeal sealing system)
Commonly Cited Test StandardsISO 2941 / 2942 / 2943 / 3723 / 3724 / 3968
Applicability NoteThe ISO 29xx / 37xx series are general test methods for hydraulic filter elements. If a supplier can only provide hydraulic filter standards, request ISO 5011 data or the original specification sheet.

Installation and Maintenance Steps

The FPG design is tool-free; a single service takes about 15 minutes.

  1. Shut down, confirm zero pressure, lock out/tag out. Stop the unit, disconnect main power, and apply lockout/tagout. Criterion: controller shows system pressure at 0.

  2. Open the FPG air cleaner access cover. Release the cover latches — FPG uses two spring latches or a twist-off cover, no tools required. Criterion: latches intact, cover not deformed.

  3. Remove the old element. Grip the polyurethane end cap and pull straight out. Criterion: note that the RadialSeal design has no gasket to peel off. If a leftover gasket is found on the housing outlet tube, a non-original part was previously fitted and must be cleaned out.

  4. Inspect the Vacuator dust valve. Check the rubber duckbill valve at the base of the housing. Criterion: valve opens and closes freely, no caked dust, no blockage. This is the most frequently skipped step in FPG maintenance and the most costly to ignore — a blocked dust valve disables the pre-cleaner stage, shifting the full dust load onto the primary element and sharply shortening its life.

  5. Check the pre-cleaner stage and dust traces inside the housing. Look for dust bypass tracks and abnormal build-up in the pre-cleaner swirl zone. Criterion: no dust tracks on the inner wall; if tracks are present, inspect the sealing surfaces.

  6. Fit the new element. Push 49164395 into the housing until the polyurethane end cap contacts the outlet tube. Criterion: end cap seated against the outlet tube; no gasket is needed or permitted.

  7. Refit the cover and check the restriction indicator. Refit the access cover and secure the latches. Confirm the intake restriction indicator reads in the green zone; if resettable, press to reset and confirm it returns correctly. Criterion: green-zone reading, indicator functioning.

  8. Start up and record. Start the unit, run to operating temperature, then read intake restriction. Criterion: restriction within the new-element baseline range; record date, running hours, and restriction reading.

Installation rule: do not start the unit before the element is seated. If the RadialSeal element is not fully pushed in, air bypasses directly through the gap between end cap and outlet tube — both the pre-cleaner and primary element are effectively bypassed, equivalent to running with no filter at all.

FAQ

What specification is 49164395?
A two-stage RadialSeal primary element built to the Donaldson FPG10 specification. The integrated tangential pre-cleaner removes roughly 85% of coarse dust first; the primary element handles fine filtration.

Is it interchangeable with 49101637?
No. 49101637 is FPG09, with different dimensions and rated airflow. Confirmation is simple: read the specification marking on the end cap of the element currently installed — FPG10 means order this part, FPG09 means order 49101637.

Why does this element have no gasket?
Because it uses RadialSeal radial sealing. The polyurethane end cap itself seals against the housing outlet tube, so no glued gasket or separate seal ring is needed. Fewer parts, fewer failure points, and less chance of incorrect installation.

What does the Vacuator dust valve do?
It is the dust discharge port for the pre-cleaner stage. Coarse dust separated by the swirling airflow falls to the base of the housing and discharges automatically through the Vacuator valve. Once the valve clogs, the pre-cleaner stage stops working entirely and all dust loads the primary element. Inspect it at every element change — this is the key maintenance action for the FPG design.

How often should it be replaced?
The recommended interval is 2,000 hours or 3 months, whichever comes first. For greater accuracy, follow the intake restriction indicator: schedule replacement once restriction enters the yellow zone. In high-dust sites, replace earlier based on indicator readings.

Can the element be blown clean and reused?
No. This is a dry, single-use element. It cannot be washed or reverse-blown with compressed air — reverse blowing damages the media fibers and creates invisible channels that let unfiltered air pass through, which is more dangerous than not changing the element at all.

Can a gasket be added to improve sealing?
No, and it is unnecessary. RadialSeal relies on radial compression of the end cap itself. Adding a gasket pushes the element away from the outlet tube and breaks the seal fit, causing bypass.

The restriction indicator never moves — is that normal?
No. A stuck indicator is a common failure point and can give a "clean" reading even when the element is actually clogged. Press-check its return action at every service; if it has failed, replace the element on a conservative time-based interval until the indicator is repaired.

How does the FPG plastic housing compare with metal housings?
The FPG molded housing is corrosion-resistant, lightweight, and vibration-tolerant, and will not rust in coastal salt-spray or damp environments. Tool-free servicing also speeds up on-site maintenance. This is a key reason the FPG series is widely used on construction machinery and mobile equipment.

How can I be 100% certain this is the right part?
Three steps: (1) read the specification marking on the end cap of the installed element and confirm it is FPG10; (2) measure the old part's outer diameter and length against 208 mm and 409 mm; (3) if the old element has been discarded, provide the model marking on the air cleaner housing and we will cross-reference it against the FPG specification.

Compatible Equipment

This element is supplied to the Donaldson FPG10 specification and fits Ingersoll Rand screw air compressors equipped with an FPG10 air cleaner.

FPG10 is a Donaldson air cleaner assembly specification used by OEMs as a standard intake filtration unit. The key checks are:

Check ItemSpecification
Air Cleaner SpecificationDonaldson FPG10 (elements interchangeable with the FRG10 series)
Air Cleaner Rated AirflowUp to 346 cfm / 9.8 m3/min
Role in AssemblyPrimary Element
Other Specification in SeriesFPG09 — part number 49101637, different dimensions and airflow, not interchangeable
Sealing SystemRadialSeal (polyurethane end cap radial seal)

How to confirm fitment

  1. Preferred: read the specification marking on the installed element's end cap. FPG10 means this part fits; FPG09 means order 49101637.
  2. Alternative: measure the old part's outer diameter and length against 208 mm x 409 mm.
  3. Fallback: provide the model marking on the air cleaner housing or a photo of the unit nameplate, and we will cross-reference against the FPG specification.

Note on model coverage

Donaldson FPG10 is a general-purpose air cleaner used by multiple OEMs, so fitment for this element is not limited to one specific model list. The correct basis for judgment is the fact that the air cleaner specification is FPG10, not the unit model itself. If the air cleaner specification is not marked on the unit nameplate, confirm using any of the three methods above.

Related Components

The FPG10 air cleaner is a complete system. Beyond the primary element, seven components are serviced together with this part. Listed below by component, function, and inspection point:

ComponentFunctionInspection Point
Safety ElementBackup element inside the primary element, protecting downstream components if the primary element is damaged or during change intervalsTypically replaced on the same or alternating interval as the primary; check media for damage
Vacuator Dust ValveAutomatic dust discharge port for the pre-cleaner stage, expelling centrifugally separated coarse dustCheck at every element change: valve must open and close freely, no caked dust, no blockage
Restriction IndicatorIndicates element clogging level; the authoritative basis for replacement timingCheck needle return action; ensure the connecting line is clear
Access Cover and LatchesTool-free opening and closing structure of the FPG housingCheck latches for cracks and cover for deformation; no air leakage once locked
FPG Housing AssemblyMolded plastic housing with tangential inlet and pre-cleaner swirl zoneCheck inner wall for dust bypass tracks; check plastic parts for cracks
Intake Hose and ClampsConnects the air cleaner to the unit intake ductCheck for cracks, aging, and looseness — bypass leakage is as harmful as running without a filter
Other Primary Elements in SeriesFPG09 — part number 49101637Different dimensions and airflow; not interchangeable — keep separate in stock

Companion replacement advice: maintenance value in the FPG10 system centers on whether the pre-cleaner stage is working. When changing the primary element, inspect the Vacuator valve and restriction indicator at the same time. If either small part fails, primary element life drops noticeably — they cost far less than the primary element but determine how long it lasts.